501-500-8025
Vascugenix Logo
Vascugenix Speed Torque

Accuracy, Speed, Control

When Time Means Everything

Accuracy, speed, and control are everything when performing interventional procedures.  The speed torque was engineered with the physician and the patient in mind.  Our patented device uses a quick click and toggle design to improve speed in positioning the device, and accuracy in maneuvering through tortuous lesions.   Speed torque is ergonomically designed for single handed use, allowing rapid position changes, improved visualizaiton and physician control of the guidewire. 

Speed-Torque

Better than the competitors

  • Single-Hand Use
  • Use Without Visual Ques
  • Doesn’t Bend Wire
  • Non-Slip Grip

Toggle

Simply push the distal end of the toggle to “click” and lock onto the wire – no need to continuously press to hold the wire. Depress the proximal end of the toggle to disengage the wire and the Speed-Torque slides freely on the wire.

Efficiency

Our patented lure tip seamlessly attaches to the introducer eliminating the need to remove the introducer during the procedure.

Handle

Familiar laser-cut, knurled handle for consistent comfort, tactile grip, and slip resistance.

 

Low Profile

When the toggle is engaged on the wire it will not interfere with torquing and positioning of the wire.

Luer Tip

The male luer tip allows the torque device to be attached to the introducer for single unit efficiency.

 

No Wire Damage

The toggle’s locking arm is made of plastic and won’t damage or deform lubricious-coated wires.

Improving both Safety and Speed for Interventional Clinicians.

General Specifications

Description: Designed to be secure to the proximal portion of a guide wire with a
diameter of 0.009”, 0.014” or 0.018”. This device should only be used by
physicians trained in invasive vascular procedures.

Intended use: Vascular procedures in conjunction with interventional and/or
diagnostic devices to facilitate the steering of the guidewire within vascular
anatomy.

Single Use: Not designed to be re-sterilized or reused on another patient.

Sterilization Method: Electron Beam Irradiation, Non-Pyrogenic.

Bore Size: 0.009-0.022”*

Latex Free: Yes

Speed Torque Product Specifications

Speed Torque Product Comparison

Regulatory Summary

Establishment Registration & Device Listing

Proprietary Name: Speed-Torque®
Classification Name: WIRE, GUIDE, CATHETER, EXEMPT
FDA Product Code: PTL
FDA Classification: Class II, 510(k) Exempt
Regulation Medical Specialty: Cardiovascular
Regulation Number: 870.1330
GMP Exempt: No